Pig farm computers and automation

All the series of microprocessors that Cavenco manufactures and develops every day, are designed by the best professionals and the best team in our R&D department, controlling temperature, humidity, ventilation, cooling, heating, lighting, windows, alarms, weight, water consumption and feed consumption, as the client requires.
Cavenco designs and manufactures electronic equipment for many companies that are marketed with various brands.
MICROPROCESSORS FOR PIG FARMS
R 1000
— Ventilation control to 6A
— Heating, cooling or alarm control
— 1 temperature sensor

Serie 5000
Mod. 5010
— Ventilation control to 6A
— Alarm, heating and cooling
— 1 temperature sensor
— Analogic output 0-10V
Mod. 5013
— Ventilation control to 6A
— Alarm, heating, cooling, auxiliary ventilation and second heating (on/off)
— 1 temperature sensor
— 1 heating sensor
Mod. 5015
— Ventilation control to 6A
— Heating control with analogic output 0-10V with SPV
— Alarm, heating, cooling, auxiliary ventilation (on/off)
— 1 temperature sensor
— 1 heating sensor

Serie 5000 "new generation"
— CYCLING SYSTEM
— ONE OR TWO TEMPERATURE SENSORS
— THREE TYPES OF VENTILATION
— REGULATED WALL SINGLE PHASE:
- SINGLE PHASE CHIMNEY
- THREE PHASE CHIMNEY
— THREE GROUPS OF VENTILATION (ON/OFF)
— COOLING
— HEATING (ON/OFF)
— HUMIDITY SENSOR
— WATER CONSUMPTION
— THREE TYPES OF HEATING PIGLETS:
- REGULATED ELECTRIC
- WATER REGULATED
— REGULATED AIR INLET
— EMERGENCY INLET:
- POSIBILITY OF REGULATED SETUP

Serie 7000
— TWO TEMPERATURE SENSORS
— THREE GROUPS OF VENTILATION (ON/OFF)
— COOLING
— HEATING ON/OFF
— THREE REGULATED WINDOWS (TWO + CHIMNEY)
— HUMIDITY SENSOR
— WATER CONSUMPTION
— EXTERIOR SENSOR
— ONE REGULATED VENTILATION GROUP
— CHIMNEY INLET BY TIMING OR POSSITION
— ANEMOMETER

NEW 4010
— REGULATED VENTILATION OF SINGLE PHASE UP TO 40A
— A TEMPERATURE SENSOR
— ON/OFF HEATING
— ON/OFF COOLING
— ALARM RELAY

NEW 4020
— REGULATED INLETS BY TIMING
— TWO TEMPERATURE SENSORS
— COOLING
— HEATING
— ALARM RELAY

ACCESSORIES
MANUAL REGULATOR P-14
—HEATING PLATES CONTROL UP TO 14a
— 8, 10, 12 OR 14 SWITCH
— INDIVIDUAL SWITCH FOR EACH PLATE

ALARM
– 2 CABLE INPUT
– 6 WIRELESS INPUT
– GSM MODEL FOR SIM CARD
– TWO REMOTERS
– SMS NOTIFICATION TO 3 NUMERS
– VOICE NOTIFICATION TO 3 NUMBERS
– POWER FAILURE DETECTION
– 2 THERMOSTAT (MAXIMUM AND MINIMUM)

SPV regulator
– Power supplement for 1 or 2 outputs
– Maximum power 1 output up to 16 amps
– Maximum double output power up to 30 amps

Spiral thermostat

Request information